Thermostat, Grounding, Electric power supply – Kenmore 5EW1.75 User Manual

Page 18: Oil burner wiring, Electrical connections

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Thermostat

Install a 24"VoIt thermostat (not provided) in a proper location. The location of the thermostat has an
important effect on boiler system operation. BE SURE TO FOLLOW THE INSTRUCTIONS INCLUDED

WITH THE THERMOSTAT.

Grounding
Permanently ground the boiler according to local codes and the National Electrical Code. Run a 14 gauge or

heavier copper wire from the boiler to a grounded connection in the service panel or a properly driven and
electrically grounded ground rod.

ELECTRICAL CONNECTIONS

WARNING

Turn off electric power at fuse box before making any

line voltage connections. Follow local electrical codes.

Electric Power Supply

All electrical work must conform to your local codes as well as the National Electrical Code. If you are not

familiar with wiring and codes in general, have a competent electrician do this job.

On packaged boilers, the boiler controls are all wired at the factory. You need only connect a 115 volt

electrical supply to the LI and L2 terminals on the aquastat relay and two thermostat wires to the T and T

terminals on the same aquastat relay (see figure below).

Run a separate circuit from a separate overcurrent protection device in your electrical service entrance panel.
This should be a 15 ampere circuit. Locate a shut-off switch at the boiler. It must be turned off during any
maintenance. Solder and tape or securely fasten these connections with wire nuts.

Oil Burner Wiring

For boilers packaged with oil burners, the burners are wired at the factory. For boilers shipped knockdown
or packaged without a burner, wiring connections are shown in the electrical wiring diagrams of this manual.

115V 60 CYCLE

16

Advertising
This manual is related to the following products: