Installation Instructions (cont’d)

AWARNING

A gas water heater cannot operate properly without the cor­

rect amount of air for combustion. Do not install in a con­
fined area such a closet, unless you provide air as shown in

the “Locating The New Water Heater” section. Never

obstruct the flow of ventilation air. If you have any doubts or

questions at all, call your gas company. Failure to provide the
proper amount of combustion air can result in a lire or explo­
sion and can cause DEATH, SERIOUS BODILY INJURY, OR

PROPERTY DAMAGE.

AWARNING

If this water heater wll be used in beauty shops, barber shops,
cleaning establishments, or self-service laundries with dry
cleaning equipment, it is imperative that the water heater or
water heaters be installed so that combustion and ventilation
air be taken from outside these areas. Refer to the “Locating
The New Water Heater” section of this manual and also the

latest edition of the National Fuel Gas Code, ANSI Z2Z3.I, also
referred to as NFPA 54 for specifics provided concerning air
required.

Combustion Air and Ventilation

When determining the installation location for a power vent

water

heater,

snow

accumulation

and

drifting

should

be

consid­

ered in areas where applicable.

VENTING CLEARANCES

• 0" clearance for 3" (or optional 2") PVC, ABS or CPVC Schedule

40 vent piping from combustible surfaces.

9

12" minimum from the ground, 9" ceiling overhangs. Figure 2.

9

The Power Vent outlet terminal shall terminate at least 36" above

any forced air inlet located within ] 0 feet. Figure 3a.

9

The Power Vent outlet terminal shall terminate at least 9" below, 9"

horizontally from or 9" above any door, window or gravity air inlet

into the building. Figure 3a.

9

18” minimum in all directions from any obstruction that may

interfere. Figure 3b.

9

18" minimum from other gravity or natural appliance outlet vents

when directly above or 135° to either side of center line. Figure 3c.

9

36" minimum from any ourler vents when directly below or 45° to

either side of center line. Figure 3c.

9

36" minimum in all directions from any other forced air appliance

outlet vent. Figure 3c.

9

The location selection must provide clearances for servicing and

proper operation of the water heater. Figure 4.

9

Vent termination must

not

be within 4 feet of any items such as gas

meters, gas valves or other gas regulating equipment.

9

The venting system must be installed in a manner which allows

inspection of the installation of the venting pipes and joints as well

as

periodic

inspection

after

installation

as

required

by

ANSI

Standards.

_______________ AWARNING_________________

Vent termination must not be within 4 feet of any items such as
gas meters, gas valves or other gas regulating equipment.

AWARNING

Failure to have required clearances between water heater and
combustible material will result in a fire hazard.

Figure 2

Figure 3c

-

any

other

outlet

vent

Must maintain
adequate service
and maintenance
accessibility. __ _

Figure 4

. TrT'

y' . '

/

Range ot degrees

available far vent

pipe installation.

10