Venting (cont’d), Installation instructions (cont’d) – Kenmore 153.335963 User Manual

Page 21

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Venting (cont’d)

ALL MODELS

3" PVC Schedule 40 vent piping:

1.

A3" ABS Schedule 40-45° vent cap with wire screen is sup­

plied with the water heater,

2.

A 5'

section of 3" PVC Schedule 40 pipe (more may be

required and must be supplied locally).

3.

3" PVC, ABS or CPVC Schedule 40 piping and fittings are

acceptable

materials

for

the

vent

system

on

all

40

gallon

models and 50 gallon 40,000 BTU/HR models.

Installation Instructions (cont’d)

ALL 40 GALLON AND 50 GALLON 40,000 BTU/HR

MODELS — OPTIONAL 2" VENT PIPING

2" PVC Schedule 40 vent piping:

1.

A wire screen ro fit a 2" Schedule 40-45° vent cap is supplied

with the water heater.

2.

A 3" PVC Schedule 40 pipe, minimum length of 3" (must

be supplied locally).

3.

A

3"

to

2"

PVC

Schedule

40

reducer

(must

be

supplied

locally),

4.

2" and 3" PVC, ABS, or CPVC Schedule 40 piping and fit­

tings

are

acceptable

materials

for

the

vent

system

on

all

40

gallon

and

50

gallon

40,000

BTU/HR

models

and

must

be

supplied locally.

2" SCHEDULE 40 PVC PIPE

s 3" TO 2" PVC REDUCER

3" SCHEDULE 40 PVC PIPE
(MINIMUM LENGTH 3")

&

=1

21