Use without power cord (cont’d), Wiring diagram, Venting – Kenmore 153.335963 User Manual

Page 16: Awarning, Venting -21, Installation instructions (cont’d)

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Instructions (cont’d)

USE WITHOUT POWER CORD (cont’d)

3. A standard

V"

conduit opening has been made in the water

heater junction box for the conduit connection.

4. Use wire nuts and connect the power supply wiring to the

wires inside the water heater’s junction box,

5. The water heater must be electrically “grounded” by the

installer, A green ground screw has been provided on the

water

heater’s

junction

box.

Connect

ground

wire

to

this

location.

For

complete

grounding

details

and

all

allowable

exceptions,

refer

to

local

codes

or

in

the

absence

of

local

codes, with the latest edition of the National Electrical Code,

ANSI/NFPA 70.

6

. Replace the wiring junction cover using the screw

provided.

WIRING DIAGRAM

Venting

AWARNING

To insure proper venting of this gas-fired water heater, the cor­
rect vent pipe diameter must be utilized. Any additions of

other gas appliances on vent with this water heater will
adversely affect the operation of the water heater.

The combustion and ventilation air flow must not be obstructed.

AWARNING

The vent pipe from the water heater must slope upward 1/4

Inch per linear foot.

,

All vent gases must be completely vented to the outdoors of the

structure (dwelling).

AWARNING

The water heater with draft hood installed must be properly

vented to a chimney which terminates outdoors. Never oper­
ate the water heater unless it is vented to the outdoors and has

adequate air supply to avoid risks of improper operation, explo­
sion or asphyxiation.

AWARNING

Obstructed or deteriorated vent systems may present a serious
health risk or asphyxiation.

16