Installation Instructions (cont’d)

Installation Checklist

BEFORE LIGHTING THE PILOT:

Check the gas lines for leaks.

a. Use a soapy water solution. DO NOT test for gas leaks

using a match or open flame,

h. Brush the soapy water solution on all gas pipes, joints and

fittings,

c. Check for bubbling soap. This means you have a leak.

Turn “OFF” gas and make the necessary repairs.

d. Rechcck for leaks.

e. Rinse off soapy solution and wipe dry.

Is

the

new

temperature-pressure

relief

valve

properly

installed

and

piped

to

an

adequate

drain?

See

“Temperature-Pressure

Relief Valve” section.

Are

the

cold

and

hot

water

lines

connected

to

the

water

heater

correctly?

See

“Water

Piping”

instructions

in

the

“Installing the New Water Heater” section.

Is the water heater completely filled with water? See “Filling”

instructions

in

the

“Instating

the

New

Water

Heater”

sec­

tion.

Will

a

water

leak

damage

anything?

See

the

“Locating

the

New Water Heater” section.

Is

there

proper

clearance

between

the

water

heater

and

any­

thing that might catch fire? See the “Locating the New water

Heater” section.

Do

you

have

adequate

ventilation

so

that

the

water

heater

will

operate

properly?

See

“Combustion

Air

and

Ventilation”

in the “Locating the New Water Heater” section.

Is the draft hood vent piping properly secured? See “Venting”

instructions

in

the

“Installing

the

New

Water

Heater”

sec­

tion.

Is

there

proper

clearance

between

the

vent

pipe

and

anything

that

might

catch

on

fire?

See

“Venting”

instructions

in

the

“Installing the New Water Heater” section.

Is the vent pipe properly sloped and does the vent terminate

outdoors?

See

“Venting”

instructions

in

the

“Installing

the

New Water Heater” section,

.

Do you need to call your gas company to check the gas pipe

and its hookup?

VENT PIPE TO

OUTDOORS

COLD

TEMPERATURE-

PRESSURE RELIEF

VALVE

DISCHARGE PIPE

(Do not cap or plug)

TEE

--------------

DRIP LEG---------

(Sediment trap)

PIPE CAP---------------- VVfe

"AUTfflIATIC STORAGE WATER

HEATER" SUITABLE FOR WATER

(POTABLE) HEATING ONLY

MCDEL NUMBER CAfitMiTY

EQUIPWD ANSZSV10

FOR MfUr RECOVERY SEf

UALNLMBER

OAS BnjkHH QM.AW.

MAXIMUM HYOnOSTATIC QAS PRESSURE IN W.C

V№*nNG mOBUHC feUUI MMMftMWSCU» tâtUtfOUO

150

P.a.1 W.C W.C. W-0

MODEL RATING PLATE

23

Advertising
This manual is related to the following products: