Installation Instructions (cont’d)

VENTING

SYSTEM

EXAMPLE

INSTALLATIONS

FOR ALL MODELS

The

vent

piping

cannot

under

any

circumstances

be

run

down­

hill.

The vent piping can be instiled as follows;

1. No more than

3

elbows

can

be used.

3.

The

total

vertical

and

horizontal

run

cannot

exceed

35'

for

3"

vent

piping

(20'

maximum

if

2"

vent

piping

is

used

on

40,000

BTU/Hr.

models)

with

a

maximum

of

three 90° elbows.