12. ERROR MESSAGE TABLE

EM 1-31059

CMT Operation Mode

• CMT Operation Mode

Control lock: PROG./CMT.

Message

Cause

Solution

MISMATCH SPEC.

Mismatch of the model type.

Mismatch of the base unit.

Mismatch of the PLU capacity.

Depress the CLEAR kev.

Mismatch of the tape contents.

Mismatch of the scale capacity.

BAD TAPE OR CMT

Parity error

Depress the CLEAR key.

Framing error

overrun error

Data error

Hardware error

Change the tape or CMT Loader.

TIME OUT ERROR

Time out error

Depress the CLEAR kev.

Memory Card Operation Mode

Control lock: PROG./CMT.

Message

Cause

Solution

MEMORY CARD N.G.

Memory card is not inserted.

Depress the CLEAR kev and
insert the memory card.

Memory card trouble.

Depress the [CLEAR
replace the memory c

key and

ard.

NO FORMAT OR
ВАТТ

The memory card is not initialized.

Depress the CLEAR kev and
initialize the memory card.

The memory card has no battery,
or the battery in the memory card
has run down.

Depress the CLEAR kev and out a
battery or replace the battery.

NO MEMORY CARD

The memory card has come off
during data transfer.

Depress the CLEAR I kev and
repeat the data transfer operation.

MEMORY CARD FULL

The memory card is full and no
more data can be saved.

Depress the CLEAR kev and

replace the memory card.

FORMAT ERROR

The memory card has no data to
be loaded into the file or verified.

Depress the CLEAR

key.

DATA ERROR

When the data stored in the
memory card and the data file are
compared, they are found to be
different.

Depress the CLEAR

key.

DIFF.

#

OF DATA

When the number of logos stored

in the memory card and that in the
logo file are compared, they are
found to be unequal.

Depress the

I

CLEAR

I

kev.

12- 2