7. PROGRAMMING PROCEDURES

EMI-31059

Menu No. 13

Menu No. 13

• Switching In-Llne/Off-Llne

When the SL-6600 is used as a satellite in an in-line system, the “ID No.” and “Transmission delay
time” can be set by the following procedure.

Select programming
menu #13.

Select the in-line
system.

The ID # can be set
when initial set #7-5

is “0”.

The transmission
delay time can be

set when In-line
system is selected

for TMCC-3.

1

PROG.

ON-LINE/LOCAL

P

13

OFF-LINE

P13 DF

I—

o

OFF-Line —► TDLC

------TMCC-3

FDLC -1

i

---- 1

ex.)

ENTER

ENTER

TMCC-3 (TR-TIME)

P13 b3 th

(Range; 1 -9)

TMCC-3 (TR-TIME)

PROG.

(Select another
programming menu.)

TMCC-3 (I.D.#)

P13 b3

Id 0

r

TMCC-3 (I.D.#)

5

0

(Range: 0~255)

P13 b3 Id 50

P13 t3 th 3

TMCC-3 (I.D.#)

P13 b3

Id 50

ON-LINE/LOCAL

P

13

NOTE: • At present, the SL-6600 cannot be used with the in-line system of TDLC.

The TMCC-3 baud rate is fixed to 4800 BPS.

To use the SL-6600 in off-line, select OFF-LINE with the key then press the ENTER
key.

Table 6: Transmission Delay Time Table

TR-TIme (ms)

TR-TIme (ms)

1

20 ~ 39

6

120 - 139

2

40 ~ 59

7

140 ~ 159

3

60 - 79

8

160 - 179

4

80 ~ 99

9

180 ~ 199

5

too ~ 119

7-44