Chapter 2: Programming

TruVision Analog PTZ Camera Configuration Manual

31

Alarms

Alarm inputs and linked actions

This section explains how to configure the PTZ camera to respond to alarm events with
alarm linked actions, such as calling presets, Preset Tours, Shadow Tours, scanning, etc.
See Figure 13 below.

Figure 13: Alarm settings menu

To select an alarm number:

1. Go to

MAIN MENU

>

SYSTEM SETTINGS

>

ALARM

>

ALARM SETTINGS

.

2. Move the cursor to

ALARM NUM

and click

IRIS+

to enter edit mode.

3. Click the up and down buttons to select the alarm number to be configured.

4. Click

IRIS+

again to confirm and exit edit mode.

Note: You can configure up to seven alarms.

To set an alarm input:

1. Go to

MAIN MENU

>

SYSTEM SETTINGS

>

ALARM

>

ALARM SETTINGS

.

2. Move the cursor to

ALARM INPUT

and click

IRIS+

to enter edit mode.

3. Click the up and down buttons to set the input status. Select

OPEN

(Normally open),

CLOSE

(Normally closed), or

N/O

(disable the alarm input).

4. Click

IRIS+

again to confirm.

Note: If the status is set to OPEN, an alarm is triggered by a high voltage level. If the
status is set to CLOSE, alarm is triggered by low voltage level. If the status is set to
OFF, it is triggered when the input channel is shut off.

To configure the alarm linkage action:

You can specify the linked action when an alarm occurs. On the

TRIGGER ACTION

submenu, set the alarm action as preset 1-8, shadow tour 1-4, preset tour 1-8, panning