Exception alarms

You can set up the camera to notify you when irregular events occur and how
you should be notified. These exception alarms include:

• HDD Full: All recording space of NAS is full.

• HDD Error: Errors occurred while files were being written to the storage, no

storage or storage had failed to initialize.

• Network Disconnected: Disconnected network cable.

• IP Address Conflicted: Conflict in IP address setting.

• Illegal Login: Wrong user ID or password used to login to the cameras.

Figure 10: Exception menu

To define exception alarms:

1. In the

Events

folder, click the

Exception

tab to open its window.

2. Under

Exception Type

, select an exception type from the drop-down list.

3. Check the checkbox to select the linkage method.

4. Click

Save

to save changes.

Alarm inputs and outputs

To define the external alarm input:

1. In the

Events

folder, click the

Alarm Input

tab to open its window.

2. Choose the

Alarm Input No.

and the

Alarm Type

. The alarm type can be NO

(Normally Open) and NC (Normally Closed). Enter a name for the alarm input.