Chapter 11: Alarm settings

100

TruVision NVR 21(S/P) User Manual

Video analytics

VCA (video content analysis) is the computerized analysis of video to detect events of
interest. This function is only available on the TVN 21S. When the function is enabled,
the recorder can handle VCA alarms generated by Interlogix cameras that support the
VCA feature.

To enable the function, go to

Camera Management

>

VCA

. You can then set the

trigger channel, schedule, and rules for the analysis. For further information on these
options, see “Motion detection schedules” on page 89.

Setting up system notifications

Setting up system notifications instructs the recorder to alert you when irregular events
occur and how to alert you to the event.

You can quickly check the system status by looking at the status LEDs on the front
panel. When there is an irregular event with the system, an icon appears on screen to
also alert you. See “Status information” on page 29 for further information.

The system notifications include:

• HDD Full: One installed HDD is full (overwrite option is disabled).

• HDD Error: Errors occurred while files were being written to the HDD, no HDD

installed or HDD had failed to initialize.

• Network Disconnected: Disconnected network cable.

• IP Conflicted: Conflict in IP address setting.

• Illegal Login: Wrong user ID or password used.

• Abnormal Record: Recording failed due to encoder or HDD problems.

Abnormal Array: Errors occurred with the array.

Hot Spare Exception: Errors occurred with hot spare HDD.

See “Description of alarm notification types” on page 95 for information on the different
alarm notification types available.

To set up system notifications:

1. Click the

Alarm Settings

icon in the menu toolbar and select

Notification

.

2. Select a notification type. See “Description of alarm notification types” on page 95

for more information.

3. Check one or more response options: Audible warning, notify surveillance center,

send e-mail, trigger alarm output.

4. Click

Apply

to save the settings.