Eclipse Combustion AIRHEAT AH-MA User Manual

Page 11

Advertising
background image

Eclipse AH-MA Air Heat Burner v2, Design Guide 160, 8/1/05

11

2) From the “Operating Range” chart in Data Sheet No. 160, the maximum

heat input at 0.7"w.c. air pressure drop is 800,000 Btu/hr/ft. The flame

length from the “Flame Length” chart in Data Sheet No. 160 is 30".

Burner length, feet = 6,240,000 Btu/hr = 7.8 feet; round up to 8 feet.

800,000 Btu/hr/ft

3) Minimum: Btu/hr = 1.3 X 60,000 X 5 = 390,000 Btu/hr.

4) Minimum per foot = 390,000 Btu/hr = 48,750 Btu/hr/ft.

8 ft.

5) From the “Operating Range” chart in Data Sheet No. 160, the

minimum input at 0.7” w.c. is 20,000 Btu/hr/ft. Therefore, the

burner can operate over the desired input range.

Layout of the burner sections
Once the lineal feet of burner has been determined, use Figure 3.2

and the criteria below to define the burner geometry.
For optimum burner performance and a uniform temperature profile,

even gas and air flow throughout the burner is essential. The following

guidelines should be used to lay out a burner:
1) Every leg of a Tee or Cross section must be separated from another

Tee or Cross section by at least 150mm (6") of burner.

2) Include the proper number of gas feed inlet sections. Use Table 3.1

as a guide to the number and size of gas feed inlets required based

on the length of the burner.

Table 3.1 Gas Feed Inlet Capacities

Example: A six-foot burner for standard gas pressure will use 2"

N.P.T. rear inlets to supply gas. How many gas inlets are required?
Solution: Each 2" back inlet can supply 4 feet of burner.

Therefore, = 1.5, or 2 inlets are required

3) Space gas inlets equally to assure uniform gas distribution.

6/4

1-1/2"
1-1/2"

2"
2"
2"
1"

1-1/2"
1-1/2"

2"
2"
2"

Rear

Side

Rear
Rear

Side
Side

Rear

Side

Rear
Rear

Side

300mm straight section, Cast Iron
300mm straight section
300mm straight section, Aluminum
300mm x 300mm cross section
300mm straight section
300mm straight section
300mm straight section, Cast Iron
300mm straight section
300mm straight section, Aluminum
300mm x 300mm cross section
300mm straight section

standard
standard
standard
standard
standard

Low
Low
Low
Low
Low
Low

4
3
4
6
4

.5

2

1.5

2
6
2

Gas Inlet

Pipe Size Directon

Section Type

Gas

Pressure

Max. Burner

Length Per

Inlet*

* Number of feet or 300mm sections

1"

Side

300mm straight section

standard

1