Verifying recent changes – Compaq 340622-002 User Manual

Page 60

Advertising
background image

5-19

Troubleshooting

Compaq SLR Tape Drive User Guide

SPECIFIC SENSE CODE

04 44 AF

Figure 5-8. A typical Tape Server log display

Verifying Recent Changes

If the drive was installed correctly but a problem has since occurred, verify any
recent changes to the system to ensure that these changes are not causing the
problem. Try the following:

1. If the system configuration has changed, remove the change to see if it

affected the drive.

2. If a board or option has been added, check its DMA, IRQ, and port

address settings for conflicts. Try removing the board or option.

3. If a SCSI device has been added, check for SCSI ID conflicts. Check for

the appropriate SCSI termination.