Version 2.0e

25

installation into an approved masonry or zero clearance fireplaces, the use of single or double-wall flue
pipe will not affect the clearance distance from the unit to any combustible materials.

DEFINED MINIMUM DISTANCES

TO COMBUSTIBLES

CLEARANCE

A. UNIT TO SIDEWALL

7”

B. UNIT TO SIDE TRIM

7”

C. UNIT TOP TO TOP TRIM

9.25”

D. UNIT TOP TO MANTLE

9.25

E. HEARTH FLOOR TO MANTLE

32”

F. NONCOMBUSTIBLE FLOOR PROTECTION, front

6”

G. NONCOMBUSTIBLE FLOOR PROTECTION, sides

6”

TABLE 3: REQUIRED MINIMUM CLEARANCES

SHROUD SYSTEM
FIGURE 11 shows the Country Flame shroud system. Black trim is standard and gold trim is
OPTIONAL and must be ordered separately. New home construction normally will not require a
shroud kit for the Crossfire because the fireplace opening can be finished out to exact Crossfire
dimensions. For pre-existing installation, a Crossfire shroud kit is available and recommended.
Country Flame offers three variations of shroud kit a) standard, b) oversize, and c) custom shroud.
Standard and oversize shrouds are available through a Country Flame Dealer and customer shrouds can
be ordered from Country Flame. Custom shrouds take 4 to 6 weeks to manufacture and require
prepayment. Each Crossfire shroud comes with installation instructions and all required hardware.
Contact a Country Flame Dealer for further details.

CF04-9200 (standard, 41.5” by 29.5” max opening) Shroud Kit Includes:

3

SHROUD PANELS, (Top, Left Side, Right Side, each painted black)

3

BLACK TRIM PIECES, (Top, Left Side, Right Side, pre-cut)

2

TRIM CORNER BRACKETS with Screws

1

ROLL OF FIBERGLASS INSULATION

CF04-9210 (oversized, fits 47.5” by 32.0” max opening) Shroud Kit Includes:

3

SHROUD PANELS, (Top, Left Side, Right Side, each painted black)

3

BLACK TRIM PIECES, (Top, Left Side, Right Side, pre-cut)

2

TRIM CORNER BRACKETS with Screws

2

ROLLS OF FIBERGLASS INSULATION

SHROUD INSTALLATION INSTRUCTIONS

1.

Complete the Crossfire chimney and combustion air (if required) installation before installing
the Crossfire shroud. The Crossfire insert should be sitting in the hearth ready for positioning
in its final location but pulled forward as far as the chimney connection will allow. Open both
the left and right access doors on the Crossfire. The installer can now begin installation of the
shroud.

2.

Remove the two ¼-

20

nuts and washers from the top of the Crossfire insert shroud mounting

studs located on the top of the Crossfire hopper. Install the top shroud panel (as shown in
FIGURE 11a) making sure the slots in the top shroud mounting flange are positioned over the
mounting studs located on top of the Crossfire hopper. Now install the two washers and then
the ¼-

20

nuts onto the studs. Do NOT tighten yet. Once installed, the nuts will hold the top

shroud in place on the Crossfire until the top shroud is adjusted in it final position. The top

Advertising