Country Flame CF-04 User Manual

Page 50

Advertising
background image

Version 2.0e

50

on/off switch at which time the system will revert to the off state. The prime state is utilized only for filling
the auger with fuel and can only be utilized from an “off state.”

The Stir Rod is controlled by the control board in one of two states: (a) when the system is shutdown, and (b)
when the system is in the burn phase. The purpose of the stir rod is to mix the fuel and air to ensure a more
efficient burn. During normal burn phase operation, the control board controls the motion of the stir rod. The
operator can press both the blue (down) and red (up) heat arrows to turn the stir rod manually. This manual
movement facilitates removal of the stir rod for maintenance or for facilitating starting a fire by rotating the stir
rod to enhance air flow during a fire’s startup.

In order to manually turn the stir arm, the up and down (red and blue) heat arrows must be simultaneously
pressed while the control is in only the OFF PHASE or the STARTUP PHASE. As long as the up and down
heat arrows are held in either the off or startup phase, the stir rod will rotate. Upon releasing either of these
arrows, the stir rod rotation will stop turning. WARNING: Keep hands or loose clothing away from the stir
pot.