Calculating the power budget, Table 6.2, Sample power budget calculation – Avaya P460 User Manual

Page 54

Advertising
background image

Chapter 6

Maximizing Avaya P460 Availability

40

Avaya P460

Installation and Maintenance Guide

Calculating the Power Budget

You can also calculate how many PSUs you need in order to provide redundancy
for a specific configuration.
You need to add the power requirements for the I/O modules installed to the base
requirement of two Supervisor modules and one Fan module. If the total is less than
the power supplied by the number of PSUs installed, an additional PSU provides
redundancy.
Table 6.2 shows a sample calculation:

Total power available:

300 W

Total power requirement:

277 W

An additional power supply will operate in redundant mode.
L Refer to “Power Requirements” on page 80 for power requirements for P460

components.

Table 6.2

Sample Power Budget Calculation

Component

Requirement (W)

Fan module

45

2 x M460ML-SPV Supervisor Modules

136

2 x M4648ML-T I/O Modules

96

Total

277

Advertising