LHEDV Series Direct Vent Insert

FP1280

RHEDV

vent termination

1/03

Flue gas exits

through the vent

termination rain

cap

1) Attach flexible pipe

to rain cap

2) Secure with clamp

3) Attach raincap to

vent termination using

three screws

Pull flexible pipe

through vent

termination

Outside combus-

tion air enters

through the lower

level of the vent

termination

Secure with

clamp and

three screws

Air Intake

Exhaust

A or B Vent with

7" Inside Minimum and

14" Outside Maximum

NOTE:

Minimum Vent Height

- 12 feet

Maximum Vent Height

- 35 feet

Exhaust collar se-

cured with clamp and

three screws

Air intake collar with

label secured with

clamp and three

screws

FP1280b

Fig. 12 Liner installatin with A or B vent.

FP1281

Flue collar plate

1/03

Flue Collar

Plate

Fastener

Plate

Cabinet

Top

10/24" x 1¹⁄₂"

Machine Screw

FP1281

Fig. 13 Remove flue collar plate assembly.

FP1282

flue collar seal

1/03

Damper

3" Flex Vent

Two Pieces

Clamps &

Screw

Fastener

Plate

Gasket

Unit

FP1282

Fig. 14 Apply high temperature sealant to end of collar.

FP1283

unit in place

1/03

Front

Frame

Damper

3" Chimney Liner

Two Pieces

Clamps &

screw

Flue Collar

Plate

Unit

FP1283

Fig. 15 Fasten with two clamps, adjust fastener plate all the
way back.

FP1284

RHEDV flue collar

plate in place

1/03

Flue

Collar

Plate

Fastener Plate

Cabinet

Top

Make sure the flue collar

plate is in contact with the

back edge of the cabinet

top

FP1284

Fig. 16 The flue collar plate must be completely in contact
with back edge of cabinet top.

FP1285

flue collar plate

in place

1/03

Fastener Plate

Cabinet

Top

Machine Screw After

Fastened

Plate Flue

Collar

FP1285

Fig. 17 Use machine screw to bolt fastener plate in place.