Fireplace & trim dimensions, Lhedv series direct vent insert – Vermont Casting LHERDV20 User Manual

Page 4

Advertising
background image

4

10004894

LHEDV Series Direct Vent Insert

N

O

P

1"

M

E

F

HEZC

specs

1/03

U

S

R

Q V

T

FP1248

Minimum fireplace

opening

1/03

Q - Fireplace opening height
R - Fireplace opening width
S - Depth of insert
T - Firebox width at insert depth(S)

LHECDV20

LHERDV20

LHECDV30

LHERDV30

A-1

20⁷⁄₈"

(530 mm)

20⁷⁄₈"

(530 mm)

26³⁄₄"

(680 mm)

26³⁄₄"

(680 mm)

B-1

30³⁄₄"

(781 mm)

30³⁄₄"

(781 mm)

38¹⁄₄"

(972 mm)

38¹⁄₄"

(972 mm)

A-2

24¹⁄₄"

(616 mm)

24¹⁄₄"

(616 mm)

28³⁄₁₆"

(716 mm)

28³⁄₁₆"

(716 mm)

B-2

37¹⁄₂"

(952 mm)

37¹⁄₂"

(952 mm)

41"

(1042 mm)

41"

(1042 mm)

A-3

24¹⁄₄"

(616 mm)

24¹⁄₄"

(616 mm)

28¹⁄₄"

(717 mm)

28¹⁄₄"

(717 mm)

B-3

38¹⁄₈"

(968 mm)

38¹⁄₈"

(968 mm)

41¹¹⁄₁₆" (1059 mm)

41¹¹⁄₁₆" (1059 mm)

A-4

20³⁄₄"

(527 mm)

20³⁄₄"

(527 mm)

24³⁄₄"

(629 mm

24³⁄₄"

(629 mm)

B-4

30⁷⁄₈"

(784 mm)

30⁷⁄₈"

(784 mm)

34⁷⁄₁₆"

(875 mm)

34⁷⁄₁₆"

(875 mm)

A-5

28"

(711 mm)

28"

(711 mm)

32¹⁄₄"

(819 mm)

32¹⁄₄"

(819 mm)

B-5

45"

(1143 mm)

45"

(1143 mm)

49"

(1245 mm)

49"

(1245 mm)

C

25⁵⁄₈"

(651 mm)

25⁵⁄₈"

(651 mm)

29³⁄₁₆"

(741 mm)

29³⁄₁₆"

(741 mm)

D

17"

(432 mm)

17"

(432 mm)

17⁵⁄₈"

(448 mm)

16³⁄₄"

(425 mm)

E

35"

(889 mm)

35"

(889 mm)

35"

(889 mm)

35"

(889 mm)

F

26⁵⁄₈"

(676 mm)

26⁵⁄₈"

(676 mm)

26⁵⁄₈"

(676 mm)

26⁵⁄₈"

(676 mm)

G

13¹⁄₂"

(343 mm)

13¹⁄₂"

(343mm)

15¹⁄₂"

(394 mm)

16¹⁄₂"

(419 mm)

H

17"

(432 mm)

17"

(432 mm)

20¹⁄₂"

(521 mm)

20¹⁄₂"

(521 mm)

I

18"

(457 mm)

18"

(457 mm)

21¹⁄₂"

(546 mm)

21¹⁄₂"

(546 mm)

J

19¹⁄₈"

(486 mm)

19¹⁄₈"

(486 mm)

22⁵⁄₈"

(575 mm)

22⁵⁄₈"

(575 mm)

K

15"

(381 mm)

15"

(381 mm)

17"

(432 mm)

18"

(457 mm)

L

10³⁄₈"

(264mm)

10³⁄⁴"

(273 mm)

11³⁄₄"

(298 mm)

12³⁄₄"

(324 mm)

M

8¹⁄₂"

(216 mm)

8¹⁄₂"

(216 mm)

8¹⁄₂"

(216 mm)

8¹⁄₂"

(216 mm)

N

37¹⁄₄"

(946mm)

37¹⁄₄"

(946 mm)

37¹⁄₄"

(946 mm)

37¹⁄₄"

(946 mm)

O

19¹⁄₈"

(486 mm)

19¹⁄₈"

(486 mm)

19¹⁄₈"

(486 mm)

19¹⁄₈"

(486 mm)

P

27¹⁄₄"

(692 mm)

27¹⁄₄"

(692 mm)

27¹⁄₄"

(692 mm)

27¹⁄₄"

(692 mm)

Q

17¹⁄²"

(444 mm)

17¹⁄²"

(444 mm)

21"

(533 mm)

21"

(533 mm)

R

25¹⁄₄"

(641 mm)

25¹⁄₄"

(641 mm)

28³⁄₄"

(730 mm)

28³⁄₄"

(730 mm)

S

13¹⁄₂"

(343 mm)

13¹⁄₂"

(343 mm)

15¹⁄₂"

(394 mm)

16¹⁄₂"

(419 mm)

T

17"

(432 mm)

17"

(432 mm)

17³⁄₄"

(451 mm)

17³⁄₄"

(451 mm)

U

13³⁄₄"

(349 mm)

13³⁄₄"

(349 mm)

15³⁄₄"

(400 mm)

16¹⁄₂"

(419 mm)

V

18"

(457mm)

18"

(457 mm)

21⁵⁄₁₆"

(541 mm)

21⁵⁄₁₆"

(541 mm)

1 = LHESSB

2 = LHESLB/LHEABSL/LHESLGA
3 = LHECSLB/LHECSLMB/LHECSLSA
4 = LHEACNSS
5 = LHETCK

T

R

I

M

F

I

R

E
P

L

A
C
E

M

I

N

I

M

U

M

O

P
E

N

I

N
G

Fireplace & Trim Dimensions

Minimum Fireplace

Insert Opening

U - Firebox depth at insert back height (V)
V - Insert back height
NOTE: LHESLGA is only available for
Model LHEC30 and LHER30

Insulation

Gas Inlet Knockout

Air Circulating Channel

Zero Clearance Kit

B

A

C

D

G

B

3" (75mm)

Dia.

H

I

J

A

K

4894

LHEDV SPEC

4/03

L

Advertising
This manual is related to the following products: