Troubleshooting the gas control system – Vermont Casting LHERDV20 User Manual

Page 18

Advertising
background image

18

10004894

LHEDV Series Direct Vent Insert

Gas Supply On

Supply Line Hooked Up

Shutoff Valve Open

NO

NO

NO

NO

Lockout Has Engaged. Wait

60 Seconds And Try Again.

For Spark At Electrode While

Depressing Piezo — 1/8" Gap To

Pilot Hood Needed.

All Wiring Connections

Replace Piezo Ignitor

For Air In The Lines

Thermopile Needs A Minimum

325mv. Adjust Pilot Flame Height.

All Wiring Connections.

Replace Thermopile

Thermocouple Needs A Minimum

of 14mv.

Defective Valve. Turn To Pilot,

Meter Should Read Greater Than

100 Mv. If Not, Replace.

Pilot Lights With

Piezo Ignitor

YES

YES

YES

YES

Pilot Stays Lit

Pilot Lights Main

Burner

System OK.

START

CHECK

Valve Is Turned On

On/off Switch Is Not Turned On.

Watch For Grounded Wires!

Thermopile Needs A Minimum

325mv.

Plugged Burner Orifice.

FP396

NVC-standing pilot troubleshooting

11/22/96

Troubleshooting the Gas Control System

Honeywell Millivolt Valve