LHEDV Series Direct Vent Insert

Instructions for RF Comfort Control Valve

The Comfort Control Valve allows remote control of
temperature, fan and flame appearance.

NOTE: The antenna should hang in free air away from
grounded metal.

Operation

1. If the manual switch is in remote position, switch it to

LOCAL. (Fig. 25)

2. Turn the pilotstat knob counterclockwise from OFF

to the PILOT position, push the knob down, and hold
in position. The pilot valve opens and allows gas to
flow to the pilot burner.

3. Push plunger on the piezo until the pilot burner is lit.

When the pilot burner is lit, the LED on the control
will come on after approximately 40 seconds and will
be continuously red. When the light turns off which
will be approximately 10 seconds after it has been
continuously red, the receiver/valve is fully powered.

4. Release the knob. The shaft will move upward. The

pilot burner should now stay burning. If the pilot
burner goes out, repeat step 2.

5. Turn the knob counterclockwise to the ON position. If

the manual switch is in the LOCAL position, the main
burner will turn on immediately.

6. ON the initial use of a transmitter, a recognition

operation is required between the receiver/valve
and transmitter. Change the switch from LOCAL
to REMOTE. Press the fan or flame button on the
transmitter within 30 seconds. The LED will blink
indicating the transmitter will now work with the re-
ceiver/valve. If the switch continues in the REMOTE
position, the transmitter will now control the main
valve, flame modulation level and fan control.

7. If the manual switch is in the LOCAL position, the

valve will be at the highest fixed pressure setting.
The transmitter will control the fan only.

Shut Off Procedure

If the manual switch is in the REMOTE position, the
transmitter can shut off the main burner and fan. How-
ever, the control is still on and a command from the
transmitter can turn on the main burner or fan.
To shut off the system, turn the pilotstat knob clockwise
to the OFF position. This action closes the main gas
and safety valves. The transmitter cannot turn on the
main burner or fan.

Transmitter Operation

Off Mode

In the OFF mode, the fireplace flame and fan are
off, the display will show OFF and displays the room
temperature. If the receiver is in REMOTE mode, the
fireplace will shut off.

On (Manual) Mode

In the ON mode, the room temperature, flame and fan
levels will be shown. MANUAL will appear next to both
the flame and fan icons.
When the control is in the ON mode, the flame and fan
levels, and delay timer are changed with the up and
down buttons. To change the flame level, press the
flame button followed by an arrow key. To change the
fan level, press the fan key followed by an arrow key.
Pushing the arrow key once will change the level by
one unit.

FP1037

Honeywell

comfort valve

3/22/00 djt

LOCAL

REM

O

TE

O

N

PILO

T

OFF

LED

Piezo Ignitor

Local/Remote

Switch

Pilotstat Knob

LED

Antenna

Fig. 25 Comfort conrol valve.

FP1037

FP1039

comfort valve

transmitter

3/27/00 djt

Display

Room Temperature

Set Temperature

Flame Height Level

Fan Speed Level

Countdown Timer

Low Battery

Flame

Up

Increases Flame

Height, Fan Speed

Timer, or Set Point

Down

Decrease

Flame, Fan

Speed Timer

or Set Point

Mode

Auto

On

Off

Countdown

Timer

Fan

Fig. 26 Transmitter diagram.