Lhedv series direct vent insert, Gas line installation, High elevations – Vermont Casting LHERDV20 User Manual

Page 6: Gas specifications

Advertising
background image

6

10004894

LHEDV Series Direct Vent Insert

Do not use this appliance if any part of it
has been under water. Immediately call a
qualified service technician to inspect the
unit and replace any part of the control
which has been under water.

Natural

LP

Minimum Inlet Pressure

5.5"

W

.

C

.

11.0"

W

.

C

.

Maximum Inlet Pressure

14.0"

W

.

C

. 14.0"

W

.

C

.

Manifold Pressure

3.5"

W

.

C

.

10.0"

W

.

C

.

Gas Inlet & Manifold Pressures

LHECDV20 / LHERDV20

LHEDV30 / LHERDV30

Certified To

ANSI Z 21.88-2005 / CSA 2.33-2005

Vented Gas Fireplace Heaters

Preparation

Before beginning, remove glass door and logs from
unit. Also check to make sure there is no hidden
damage to the unit. Take a minute and plan out the
gas,venting and electrical route. It is best to start with
the gas line first followed by the chimney liner. (Refer to
Page 9)

Gas Line Installation

When purging the gas line, the front glass
must be removed.

If gas piping from the source to the heater

location has not been accomplished, install the required
pipe. Consult local plumbing code to assure proper pipe
size.
The gas pipeline can be brought in through the rear or
the base of the heater.
NOTE: The gas line connection can be made of either
properly tinned 3/8" copper tubing, 1/2" rigid pipe or
an approved flex connector then reduced to 3/8" to the
heater. Some municipalities have additional local codes,
it is always best to consult your local authority and the
CSA- B149.1 installation code.
U.S. Installations consult the current National Fuel
Gas Code, ANSI Z223.1/NFPA 54.

Always check for gas leaks with a mild
soap and water solution. Do not use an
open flame for leak testing.

The gas control is equipped with a captured screw
type pressure test point, therefore it is not necessary to
provide a 1/8" test point up stream of the control.
When using copper or flex connector, use only
approved fittings. Always provide a union when
using black iron pipe so the gas line can be easily
disconnected for burner or fan servicing. See gas
specifications for pressure details and ratings. NOTE:
If flex connector is used, it must be kept inside of the
heater.

These gas inserts are approved for installation
in solid fuel burning masonry or zero clearance
fireplaces.

High Elevations

Input ratings are shown in BTU per hour and are
certified without deration for elevations up to
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA,
installations must be in accordance with the
current ANSI Z223.1/NFPA 54 and/or local codes
having jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370m).

Units: GIDN4B0, J23KC0, GIDN3B0, GIDN3H0,
GIDL3H0, M22KC0, M22LC0, M31A30

Gas Specifications

Max.

Min.

Air Shutter

Gas

Input Input

Setting

Model

Fuel

Control Btu/h Btu/h Front Rear

LHECDV20RN Natural Millivolt 20,000 14,000 Fully Closed

Hi/Lo

Open 50%

LHECDV20RP Propane Millivolt 20,000 15,000 Fully Closed

Hi/Lo

Open 80%

LHECDV20RFN Natural Comfort 20,000 14,000 Fully Closed

Control

Open 50%

LHECDV20RFP Propane Comfort 20,000 15,000 Fully Closed

Control

Open 80%

LHERDV20RN Natural Millivolt 20,000 14,000 Fully Closed

Hi/Lo

Open 50%

LHERDV20RP Propane Millivolt 20,000 15,000 Fully Closed

Hi/Lo

Open 80%

LHECDV30RN Natural Millivolt 30,000 21,000 Fully Fully

Hi/Lo

Open Open

LHECDV30RP Propane Millivolt 30,000 22,500 Fully Fully

Hi/Lo

Open Open

LHECDV30RFN Natural Comfort 30,000 21,000 Fully Fully

Control

Open Open

LHECDV30RFP Propane Comfort 30,000 22,500 Fully Fully

Control

Open Open

LHERDV30RN Natural Millivolt 30,000 21,000 Fully Fully

Hi/Lo

Open Open

LHERDV30RP Propane Millivolt 30,000 22,500 Fully Fully

Hi/Lo

Open Open