Lhedv series direct vent insert, Gas supply pressures, Fan kit – Vermont Casting LHERDV20 User Manual

Page 7: Fan removal instructions, Installation of trim switch for rn/rp gas valves

Advertising
background image

7

10004894

LHEDV Series Direct Vent Insert

FP297

INSTA VENT FREE

R MODEL GAS SUPPLY

8/24/96

1/2" Gas Supply

1/2" x 3/8" Shut Off Valve

3/8" Nipple

3/8" Union

FP297

Fig. 4 Typical gas supply installation.

3/8" Nip-

ple

Gas Supply Pressures

This heater must be isolated from the gas supply piping
system by closing its individual manual shut-off valve
during any pressure equal to or less than 1/2 psig
(3.45kPa).
The heater and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.45kPa).

Fan Kit

115 volt, 60 Hz. 56w (Model FK24)
NOTE: The LHERDV20 and LHERDV30 are not
designed for a fan kit.
The fan kit includes the following: fan, temperature
sensor, speed control and a 6 ft. cord. The following
explains how to start and set the fan for automatic
operation.
1. Plug in the electrical cord.
2. Start gas fire - see lighting procedures.
3. Turn on fan speed control.
4. Wait until the unit has warmed up sufficiently to

activate the temperature sensor, approx. 5-10
minutes.

5. Once fan starts, adjust speed control to desired fan

speed. The fan will now automatically come on every
time the fireplace is in operation. Should the fan not
be needed simply turn off the speed control.

The appliance, when installed must be
electrically connected and grounded in
accordance with local codes or, in the ab-
sence of local codes, with the current CSA
C22.1 Canadian Electrical Code.
U.S. Installations,
follow local codes and the
National Electrical Code, ANSI/NFPA No. 70.
Should this fan require servicing, the
power supply must be disconnected. For
rewiring of any replacement components
refer to Figure 6.

Fan Removal Instructions

1. Turn off gas and electricity.
2. Remove the front glass.
3. Remove the logs.

CAUTION: Logs may be hot!

4. For Model LHECDV20: remove burner assembly

and bracket rear log. For Model LHECDV30: remove
bracket rear log and cover fan.

5. Remove the fan mounting nuts (2 nuts). (Fig. 5)
6. Slip off the electrical connector at the motor.
7. Lift out the fan.
8. To reinstall reverse procedure.

FP1252

FK24 install

1/03

Thermal Sensor is

Attached to Burner

Base

Fan is Installed

at the Back of the

Air Intake Box

Fan Speed Control/Junction Box

Screw

Stud

Screw Stud

FP1252

Fig. 5 Fan location.

FP394

WIRING DIAGRAM

11/20/96

Fan

Temperature Sensor

Speed

Control

Black

White

Ground

FP394

Fig. 6 Wiring diagram RN/RP. NOTE: For comfort valve wir-
ing diagram refer to Page 18, Figure 27.

Installation of Trim Switch

for RN/RP Gas Valves

1. Thread wire through openings on the right side of fire-

place. Do not cut wire or insulation on metal edges.

2. Insert ON/OFF switch with wiring assembly into the

bracket switch with the pre-punched opening mounted
on the right side of the trim. (Fig. 7)

3. For left side installation, relocate the bracket switch

to the left side of the trim kit and repeat Step 2. (Fig.
8)

4. Connect wiring from the switch to the gas valve (Fig.

9a & b).

Advertising
This manual is related to the following products: