0 hardware and software operating requirements, 0 specifications, 1 unit dimensions – Keri Systems LC-208 Wiegand Elevator Control User Manual

Page 2: 2 operating temperature and humidity range, 3 power requirements, Wiegand elevator control panel

Advertising
background image

Wiegand Elevator Control Panel

1530 Old Oakland Road, Suite 100

01879-002 Rev. C

San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]

Page 2 of 24

Quick Start Guide

LC-202W/LC-208W

User card presentation to the reader is critical. To ensure that all controllers have the opportunity
to respond to a card read, the card must be presented to the reader for a greater period of time
(perhaps up to 2 seconds depending upon the length of the cable run and the number of
controllers attached to the network). This allows all antenna inputs on all controllers the time
necessary to respond to the card.

2.0

Hardware and Software Operating Requirements

All standard hardware and software requirements for Doors32 software apply (refer to the Doors32
Users Guide – P/N 01821-002). To support elevator control, the following additional software and
firmware requirements must be met.

The Doors32 software must be at revision 3.42 or greater.

The controller firmware must be at revision 6.3.42 or greater.

3.0

Specifications

3.1

Unit Dimensions

LC-200W Controller PCB with or without SB-200 Satellite Board
-

7.00 inches high by 6.00 inches wide by 1.75 inches deep, including wiring connectors

-

(17.78 cm by 15.25 cm by 4.45 cm)

LC-200W Controller PCB with an LCD-1 Alpha/Numeric Display
-

8.25 inches high by 6.00 inches wide by 1.75 inches deep, including wiring connectors

-

(20.95 cm by 15.25 cm by 4.45 cm)

LC-202W Enclosure
-

9.70 inches high by 8.20 inches wide by 2.60 inches deep

-

(24.64 cm by 20.83 cm by 6.60 cm)

LC-208W Enclosure
-

18.50 inches high by 15.25 inches wide by 4.00 inches deep

-

(47.00 cm by 38.75 cm by 10.20 cm)

3.2

Operating Temperature and Humidity Range

0°F to 140°F (-18°C to 60°C)

0% to 90% Relative Humidity, non-condensing

3.3

Power Requirements

12 VDC @ 750 mA for the LC-202W panel

12 VDC @ 3 A for the LC-208W panel

Advertising
This manual is related to the following products: