2 lc-208w/lc-208w combination, Wiegand elevator control panel – Keri Systems LC-208 Wiegand Elevator Control User Manual

Page 21

Advertising
background image

Wiegand Elevator Control Panel

1530 Old Oakland Road, Suite 100

01879-002 Rev. C

San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]

Page 21 of 24

LC-202W/LC-208W

Quick Start Guide

5.4.2

LC-208W/LC-208W Combination

Perform the following wiring instructions to accommodate an elevator application using two LC-
208W panels (up to 16 floors).

1. Make a complete set of connections to the first LC-208W panel. Refer to Section 5.3 on page 16

for all connections to the LC-208W.

2. Daisy-chain the Data0, Ground, and Data1 reader connections from W-TB-B of the second LC-

208W panel to W-TB-C of the first LC-208W panel. Make the connections per the information
in Table 9 and Figure 13 on page 22.

3. Daisy-chain the TxRx+, TxRx-, and Shield Network Communication connections from W-TB-

B of the second LC-208W panel to W-TB-C of the first LC-208W panel. Make the connections
per the information in Table 10 and Figure 14 on page 23.

4. The floor/relay connections for the second LC-208W are made according to the floor/panel

association. Refer to Section 5.3 on page 16 for all floor/relay connections to the LC-208W.
Power connections are made per the instructions in Section 5.2.4 on page 16.

Table 9: LC-208W to LC-208W Panel Wiring Connections

W-TB-B of Second Panel

W-TB-C of First Panel

Reader Ground (OUT)

Reader Ground (IN)

Data0 (OUT)

Data0 (IN)

Data1 (OUT)

Data1 (IN)

Table 10: LC-208W to LC-208W Panel Network

Communication Wiring

W-TB-B of Second Panel

W-TB-C of First Panel

TxRx - (OUT)

TxRx - (IN)

TxRx + (OUT)

TxRx + (IN)

Shield (OUT)

Shield (IN)

Advertising
This manual is related to the following products: