Quick Start Guide

LC-202W/LC-208W

3.7

Cable Requirements

RS-232 Serial Cable
-

four conductor, shielded, stranded AWG 24 wire (Belden 9534 or a heavier gauge)

-

50 foot maximum length (per RS-232 industry specification – greater lengths are not
recommended)

RS-485 Network Cable
-

one twisted, shielded pair of conductors, stranded, AWG 24 wire (Belden 9501 or a heavier
gauge)

-

4,000 foot total network length (per RS-485 industry specification – greater lengths are not
recommended)

Input Power
-

two conductor, stranded, AWG 18 wire (Belden 8461 or a heavier gauge)

-

200 foot maximum length

NOTE: On long power cable runs, the cable resistance causes a drop in voltage at the end of the
cable run. Be sure your power supply provides 12 VDC at the end of the cable run.

Readers to Panel
-

Wiegand Readers require seven conductor, shielded, stranded AWG 24 wire (Belden 9537
or a heavier gauge)

Panels Daisy-Chained
-

Wiegand Readers require three conductor, shielded, stranded AWG 24 wire (Belden 9533 or
a heavier gauge)

Output Connections
-

two conductor, stranded AWG 22 (Belden 9532 or a heavier gauge)

NOTE: The Floor Control Relay may require a heavier gauge of wire depending upon the current
demands of the elevator panel and the length of the wiring run.

NOTE: If plenum cable is required, please reference the Belden equivalent to the cable listed above.