KFE-TM-BA_IA-e-1313

7.8 Automatic adding-up

This function is used to issue and add individual weighing values automatically to the

summation memory on unloading of weighing scale without pressing

.

Menu settings:

F5 Prt“  „P prt“, see chap. 8.2
P4 CHk“  „mode 1“, see chap. 11.4

When function is activated, the indicator

AUTO

appears.

Add up:

 Place weighing goods A.

After the standstill control sounds a signal tone.

 Unload the weighing good, the weighing value is added into the summation

memory.

More weighed goods can only be added when the disp

lay ≤ zero.

 Place goods to be weighed B.

After the standstill control sounds a signal tone. Unload the weighing good, the
weighing value is added into the summation memory. Number of weighing,
followed by the total weight will be displayed for 2 sec.

 Add more weighed goods as described before.

Please note that the weighing system must be unloaded between the individual
weighing procedures.

 You can repeat this process 99 times until the capacity (max) of the weighing

system is exhausted.

After the audio sound was sounded you can remove the load or add to it.

Display and delete weighing data see chap. 7.7.