2c. site location – LAARS Mighty Therm HH-PH (Sizes 175-400) - Installation, Operation and Maintenance Instructions User Manual

Page 5

Advertising
background image

Mighty Therm HH-PH Hydronic Boilers

Page 5

Heater

Heater

Closet Installation

(unacceptable)

Room Installation

(acceptable)

Alcove Installation

(acceptable)

A closet is any 4 sided enclosure
which is less than 16* times the
total volume of all the gas fired
appliances within the enclosure.

A room is any enclosure which is
at least 16* times greater than the
total volume of all the gas fired
appliances within the enclosure.

An alcove suitable for the
installation of a heater is a
restricted section of a room not
separated from the room by a door
or partition and which meets the
minimum clearances specified in
this manual.

* When the cieling height exceeds 8 feet, you are only allowed to consider 8
feet when calculating the total volume of the enclosure.

Figure 8. Vent Damper Installation (Models 175 and
250 only).

Figure 6. Drafthood with

Adapter Plate.

Figure 7. Drafthood Switch

Receptacle.

h.

Plug the wiring for the drafthood switch into the

receptacle on the left side of the vent damper box

(see Figure 7).

i.

Do not modify the automatic vent damper

device. The venting system must be arranged so

that only the boiler is served by the vent damper

device supplied with the boiler. Provide at least

six inches clearance between the automatic vent

damper and combustible construction, and be

sure to allow access for servicing the damper.

WARNING

Do not force motor operation when the operator is
fastened to the damper by moving the damper
blade, turning the shaft, or turning the position
indicator.

2C. Site Location

2C-1. Installation Information

WARNING

Improper installation or maintenance can cause
nausea or asphyxiation from carbon monoxide in
flue gases which could result in severe injury,
property damage, or death.

Locate the boiler to provide clearances on all

sides for maintenance and inspection. There must also

be minimum distances maintained from combustible

surfaces (see Table 1 and Figure 9).

Indoors

Outdoors

Clearance from:

inch mm

inch mm

Top

37

940

Unobstructed

Water conn. side

12

305

Unobstructed

Opposite side

6

152

6

152

Front

Alcove

Unobstructed

Rear

6

152

6

152

Vent*

6

152

Flooring

Combustible

Combustible

Service clearance = 36 inches (914mm) at front of heater,

and 18 inches (457mm) at water connection side.

*1" (25mm) if double wall vent is used.

Table 1. Minimum Boiler Clearances

From Combustible Surfaces.

VENT DAMPER

DRAFT HOOD

VENT DAMPER
HARNESS

Figure 9. Alcove Installation.