1 introduction, Mighty therm – LAARS Mighty Therm2 MT2V (Sizes 500–2000 MBTU/h) - Install and Operating Manual User Manual

Page 3

Advertising
background image

Mighty Therm

2

Page 3

SECTION 1.

General Information

USING THIS MANUAL – Because Mighty

Therm2 Boilers and Water Heaters are identical

appliances, with the exception of materials of

manufacture, labels and ultimate use application,

this manual provides information for the proper

installation, operation and maintenance of all

products. Where differences exist between the

application of the appliances and their operation, the

sections pertinent to only one appliance or the other

will be so identified.

In the Commonwealth of Massachusetts, this app-

liance must be installed by a licensed plumber or gas fitter.

WARNING

The Mighty Therm2 hydronic boiler or water heater

must be installed in accordance with the procedures

detailed in this manual, or the Laars Heating Systems

warranty may be voided. The installation must

conform to the requirements of the local jurisdiction

having authority, and, in the United States, to the

latest edition of the National Fuel Gas Code, ANSI

Z223.1/NFPA54. In Canada, the installation must

conform to the latest edition of the Natural Gas

and Propane Installation Code, CSA B149.1 and/or

local codes. Where required by the authority having

jurisdiction, the installation of Laars appliances must

conform to the Standard for Controls and Safety

Devices for Automatically Fired Boilers, ANSI/

ASME CSD-1. Any modifications to the unit, its gas

controls, or wiring may void the warranty. If field

conditions require modifications, consult the factory

representative before initiating such modifications.

1.1 Introduction

This manual provides information necessary for the

installation, operation, and maintenance of Laars Heating

Systems Mighty Therm2 copper tube appliances. Read it

carefully before installation.

All application and installation procedures should

be reviewed completely before proceeding with the

installation. Consult the Laars Heating Systems factory,

or local factory representative, with any issues or

questions regarding this equipment. Experience has

shown that most operating issues are caused by improper

installation.

The Mighty Therm2 appliance is protected against

over pressurization. A pressure relief valve is fitted to

all appliances. It is installed on the outlet header, at the

water outlet of the appliance.

IMPORTANT: The inlet gas pressure to the appliance

must not exceed 13" W.C. (3.2kPa).

All installations must be made in accordance with:

1). In the U.S., the " National Fuel Gas Code"ANSI

Z223.1/NFPA54, Latest Edition and all applicable local

codes as required by the Authorities Having Jurisdiction

(AHJ), or

2). In Canada, the "Natural Gas and Propane

Installation Code", CSA B149.1, latest edition and

all applicable local codes as required by the AHJ.
All electrical wiring is to be done in accordance with:

1). In the U.S., the "National Electrical Code"

(NEC), ANSI/NFPA 70, latest Edition and all applicable

local codes as required by the AHJ, or

2). In Canada, the “Canadian Electrical Code - Part

1”, CSA STD. C22.1 and all applicable local codes as

required by the AHJ.
This appliance must be electrically grounded in

accordance with the applicable codes and standards

referenced above.

1

2

3

4

5

6 7

8

9

10

11

12

13

14

15

16

M T

2

A

C

K

1

SERIES

M T 2

SIZE

0 5 0 0
0 7 5 0
1 0 0 0
1 2 5 0
1 5 0 0
1 7 5 0
2 0 0 0

REVISION

1 - FIRST

REV

OPTIONS

CODE

X - STD
J - CSD-1,

GAP,

FM

USAGE

H - HYDRONIC
V - VOLUME WATER

FUEL

N - NATURAL
P - PROPANE

PUMP

OPTIONS

X - NO PUMP

H - PUMP MOUNTED

TACO, HARD

WATER

(MT2V)

N - PUMP MOUNTED,

TACO, NORMAL

WATER

(MT2V, MT2H)

S - PUMP MTD, TACO

SOFT WATER PUMP

(MT2V)

C - PUMP MOUNTED

B&G, HARD

WATER

(MT2V)

B - PUMP MOUNTED,

B&G, NORMAL

WATER

(MT2V, MT2H)

D - PUMP MTD, B&G

SOFT WATER PUMP

(MT2V)

ALTITUDE

A - 0' – 10,000'

LOCATION

C - INDOOR/

OUTDOOR

FIRING

MODE

K - 2-Stage

HEAT EXCHANGER

B - GLASS-LINED CAST IRON/

COPP/BRZ TRIM

(std.MT2V)

C - GLASS-LINED CASTIRON/

COPP.

(std.MT2H, n/a MT2V)

N - GLASS-LINED CAST IRON/

CU-NICKEL

(n/a MT2V)

P - GLASS-LINED CAST IRON /

CU-NICKEL, BRZ TRIM

HLW STAMP (MT2V only)

2 - GLASS-LINED CAST IRON/

COPPER / BRZ TRIM

5 - GLASS-LINED CAST IRON/

CU-NICKEL / BRZ TRIM