Thermostat board replacement procedure, Wiring diagram – LAARS U.H.E. - Service Manual User Manual

Page 15

Advertising
background image

U.H.E Service Manual

Page 15

Step 5.

Carefully disconnect all wires from thermostat

board.

Note: it may be necessary to identify wires

for proper re-connection.

Step 6.

Remove the two screws (Phillips head screw

driver) that secure thermostat board to

control panel.

Step 7.

Install new thermostat board to control panel using

screws from step 6.

Step 8.

Carefully reconnect wiring per the wire

diagram below. Reconfirm wire

connections are correct prior to putting

heater back in service

Step 9.

Restore 120 volt power supply to water

heater and confirm proper operation following

the lighting instructions on the lighting

instruction label or the lighting instruction

located in the installation and operating

instruction manual.

Step 10. Replace surround cover on top of heater.

Thermostat Board Replacement Procedure

Step 1.

Position main power switch to “OFF”

Step 2.

Disconnect (unplug) water heater from 120

volt power source.

Step 3.

Un-latch and remove top surround cover

from top of heater.

Step 4.

Locate thermostat board on control panel.

(see photo at right)

WIRING DIAGRAM

WARNING

120 volt potential exposure. Isolate the

appliance and reconfirm power is

disconnected using a multi-meter.

15

Thermostat

Board

Mounting

screw locations