Burner tube removal procedure – LAARS U.H.E. - Service Manual User Manual

Page 22

Advertising
background image

LAARS Heating Systems

Page 22

Step 1.

Position main power switch to “OFF”.

Step 2.

Disconnect (unplug) water heater from

120 volt power source.

Step 3.

Turn off gas supply to water heater.

Step 4.

Un-latch & remove surround cover from top of

heater.

Step 5.

From the gas valve, disconnect

the gas connection, PVC venting,

wire harness and silicone tubing.

Step 6.

Disconnect wire harness from

blower assembly.

Step 7.

Remove the two screws holding

each the hot surface igniter and

flame sensor in place (long reach

magnetic Phillips screw driver).

Carefully remove hot surface igniter

and flame sensor from combustion

assembly.

Step 8.

Remove the 4 nuts (7/16" wrench) holding

the burner transition in place. Lift the blower/gas

valve transition assembly from burner mounting

insert, remove gasket and set aside.

Step 9.

Remove burner tube from burner

mounting insert. See next page for

burner tube inspection procedure.

Burner Tube Removal Procedure

WARNING

120 volt potential exposure. Isolate the

appliance and reconfirm power is

disconnected using a multi-meter.

WARNING

Heater components may be HOT when performing the following steps in this procedure.

Take necessary precaution to prevent personal injury.

22

BURNER TRANSITION

MOUNTING NUTS

HOT SURFACE

IGNITER/SPARK

ROD

Advertising