Disassembly Procedure for Access to Anodes & Flue Baffles

Step 1.

Position main power switch to “OFF”.

Step 2.

Disconnect (Unplug) water heater

from 120 Volt power source.

Step 3.

Un-latch & remove surround cover from top of heater.

Step 4.

Disconnect wire harnesses to allow for removal of control panel.

Note: Where ever possible, rather than disconnecting at the control panel, follow wire

harness away from control panel and disconnect at control component location.

Step 5.

Remove the three control panel mounting screws (¼” nut driver) and remove control

panel from the water heater (see photos below).

Step 7.

Remove all collector cover

screws (5/16" socket) and

remove collector cover

(see photos at right).

Step 6.

Completely remove insulation (two pieces) from top of heater to expose collector cover

Step 8.

Photo 44 shows heater with collector cover removed allowing

access to anode rods and flue baffles.

a) for anode service, see page 39.

b) for flue baffle service, see page 40.

c) for powered anode service, see page 41.

Note: UHE100T399 models have only 1 anode

rod under the 2

nd

pass collector cover.

WARNING

Heater components may be HOT when performing the following steps in this procedure.

Take necessary precaution to prevent personal injury.

WARNING

120 volt potential exposure. Isolate the

appliance and reconfirm power is

disconnected using a multi-meter.

Collector

cover

Anode

locations

Flue

baffles

38

Control Panel

Mounting Screw

Remove Control

Panel