Mascot ii boilers and water heaters, Page 25, Figure 22. wiring diagram – LAARS Mascot ll LMC - Install and Operating Manual User Manual

Page 27

Advertising
background image

Mascot II Boilers and Water Heaters

Page 25

Figure 22. Wiring Diagram.

BLOCKED

VENT SWITCH

COM

NC

POWER PLUG 115V

BLOWER

3

1

5

1

G

POWER SWITCH

Y

24V

115V

W

BK

Y

TRANSFORMER 115 VAC INPUT 24 VAC OUTPUT

1 2

DOMESTIC

EMP. SENSOR

1

2

INLET TEMP. SENSOR

CIRCUIT

BREAKER

115V "HOT"

10A

WIRE GUIDE

24V = 22 AWG 24V = 18 AWG 115V = 18 AWG

COLOR GUIDE

BK - BLACK W - WHITE R - RED Y - YELLOW BL - BLUE BR - BROWN O - ORANGE G - GREEN P - PURPLE GR - GRAY

115 V

"HOT"

115 V

"N

EUTRAL"

115 V

"G

ROUND"

PUMP

CIRCUIT

BREAKER

24V "HOT"

2 AMP

3 WAY

WATER FLOW

VALVE

31 42

OUTLET TEMP. SENSOR

31 42

EXHAUST STACK

TEMP. SENSOR

24V COM

+24V

G

A

S

VALVE

NO

COM

WATER PRESSURE

SWITCH

1

2

3

LOCAL DISPLAY

N

C

2

3

4

5

6

7

8

1

N

O

CO

M

H2345500revA

C

O

M

N

0

FAN PROVING

SWITCH

LMC ONLY (LMH: USE JUMPER B/W 7 & 8)

Y

4
65

3
5

4
6

DPDT RELAY

G

O

LMC ONLY (LMH: USE A-STAT FOR INDIRECT)

BK

R

R

W

Y

Y

R

G

LW

C

O

SWITCH

W

BK

W

BK

1

2

34

5

6

7

8

9

10

11

12

13

14

SPARK IGNITOR

FLAME SENSOR

SYSTEM

SENSOR

ALARM

T-T OR INTERLOCK

ANALOG INPUT +

OUTDOOR TEMP.

SENSOR

ANALOG INPUT -

OUTDOOR TEMP.

SENSOR

SYSTEM PUMP

BK

BK

W

W

G

G

R

R

R

Y

Y

Y

R

G

R

Y

BR

R

O

P

BL

O

BR

Y

BL

BL

BR

Y

BR

BL

O

BR

Y

Y

P

P

PO

BL

BR

GR

GR

GR

P

P

GR

GR

Y

BR

BL

R

BK

W

Y

Y

BR

R

P

BR

BL

FLOW SWITCH

R

BK

W

ILLUM

Y

J4A

J8A

J9

J2

J1

J3

4

3

2

1

1

4

23

6
5

A

A

A

B

B

B

C

C

R

MB1

MB2

ECOM

HV SPARK

J10

CONTROL MODULE

1

2

1

2

3

7

8

2

3

4

5

6

78

12

3

4

5

6

12

3

4

5

4

5

6

6

12

3

Y

J8B

1 TERM STRIP

R

G

BK

1

3

14

2

56

BK

BK

BR

BL

1

65

43

2

J4B

Y

DRY

CONTACT

7A

GR

R

C

(OPTIONAL)

R20729

O

BLOCKED

VENT SWITCH

COM

NC

POWER PLUG 115V

BLOWER

3

1

5

1

G

POWER SWITCH

Y

24V

115V

W

BK

Y

TRANSFORMER 115 VAC INPUT 24 VAC OUTPUT

1 2

DOMESTIC

EMP. SENSOR

1

2

INLET TEMP. SENSOR

CIRCUIT

BREAKER

115V "HOT"

10A

WIRE GUIDE

24V = 22 AWG 24V = 18 AWG 115V = 18 AWG

COLOR GUIDE

BK - BLACK W - WHITE R - RED Y - YELLOW BL - BLUE BR - BROWN O - ORANGE G - GREEN P - PURPLE GR - GRAY

115 V

"HOT"

115 V

"N

EUTRAL"

115 V

"G

ROUND"

PUMP

CIRCUIT

BREAKER

24V "HOT"

2 AMP

3 WAY

WATER FLOW

VALVE

31 42

OUTLET TEMP. SENSOR

31 42

EXHAUST STACK

TEMP. SENSOR

24V COM

+24V

G

A

S

VALVE

NO

COM

WATER PRESSURE

SWITCH

1

2

3

LOCAL DISPLAY

N

C

2

3

4

5

6

7

8

1

N

O

CO

M

H2345500revA

C

O

M

N

0

FAN PROVING

SWITCH

LMC ONLY (LMH: USE JUMPER B/W 7 & 8)

Y

4
65

3
5

4
6

DPDT RELAY

G

O

LMC ONLY (LMH: USE A-STAT FOR INDIRECT)

BK

R

R

W

Y

Y

R

G

LW

C

O

SWITCH

W

BK

W

BK

1

2

34

5

6

7

8

9

10

11

12

13

14

SPARK IGNITOR

FLAME SENSOR

SYSTEM

SENSOR

ALARM

T-T OR INTERLOCK

ANALOG INPUT +

OUTDOOR TEMP.

SENSOR

ANALOG INPUT -

OUTDOOR TEMP.

SENSOR

SYSTEM PUMP

BK

BK

W

W

G

G

R

R

R

Y

Y

Y

R

G

R

Y

BR

R

O

P

BL

O

BR

Y

BL

BL

BR

Y

BR

BL

O

BR

Y

Y

P

P

PO

BL

BR

GR

GR

GR

P

P

GR

GR

Y

BR

BL

R

BK

W

Y

Y

BR

R

P

BR

BL

FLOW SWITCH

R

BK

W

ILLUM

Y

J4A

J8A

J9

J2

J1

J3

4

3

2

1

1

4

23

6
5

A

A

A

B

B

B

C

C

R

MB1

MB2

ECOM

HV SPARK

J10

CONTROL MODULE

1

2

1

2

3

7

8

2

3

4

5

6

78

12

3

4

5

6

12

3

4

5

4

5

6

6

12

3

Y

J8B

1 TERM STRIP

R

G

BK

1

3

14

2

56

BK

BK

BR

BL

1

65

43

2

J4B

Y

DRY

CONTACT

7A

GR

R

C

(OPTIONAL)

R20729

O

Advertising