Maxq family user’s guide: maxq8913 supplement – Maxim Integrated MAXQ Family Users Guide: MAXQ8913 Supplement User Manual
Page 72
Advertising
MAXQ Family User’s Guide:
MAXQ8913 Supplement
19-10
waitConvert:
move C, ADST.5
jump NC, waitConvert ; Wait for 16 samples to be captured (ADDAI=1)
move ADST.6, #0
; Stop conversion
move ADST.5, #0
; Clear data available flag
move ADST, #0000h ; Points ADDATA to data register 0
move A[0], ADDATA ; Get conversion data
move A[1], ADDATA
move A[2], ADDATA
move A[3], ADDATA
move A[4], ADDATA
move A[5], ADDATA
move A[6], ADDATA
move A[7], ADDATA
move A[8], ADDATA
move A[9], ADDATA
move A[10], ADDATA
move A[11], ADDATA
move A[12], ADDATA
move A[13], ADDATA
move A[14], ADDATA
move A[15], ADDATA
Maxim Integrated
Advertising