waitConvert:

move C, ADST.5

jump NC, waitConvert ; Wait for 16 samples to be captured (ADDAI=1)

move ADST.6, #0

; Stop conversion

move ADST.5, #0

; Clear data available flag

move ADST, #0000h ; Points ADDATA to data register 0

move A[0], ADDATA ; Get conversion data

move A[1], ADDATA

move A[2], ADDATA

move A[3], ADDATA

move A[4], ADDATA

move A[5], ADDATA

move A[6], ADDATA

move A[7], ADDATA

move A[8], ADDATA

move A[9], ADDATA

move A[10], ADDATA

move A[11], ADDATA

move A[12], ADDATA

move A[13], ADDATA

move A[14], ADDATA

move A[15], ADDATA