73M1822/73M1922 Implementer’s Guide

UG_1x22_052

10

Rev. 1.0

Begin : RESYNC

1. IF CNT1 !=1 goto 8

2. Write CHNGFS = 1 (RG0D = xxxx_1xxx).

3. Wait 20 ms.

4. READ RGO3,RG0D

5. Goto BARRIER CHECK

6. IF CNT1 !=2 goto 15

7. Write SLEEP = 1 (RG0F = xx1x_xxxx).

8. Wait 10 ms.

9. Write SLEEP = 0 (RG0F = xx0x_xxxx).

10. Wait 10 ms.

11. READ RGO3,RG0D

12. Goto BARRIER CHECK

13. Resync Failed. Report to user and reset or power down entire device.

End