5 Off-Hook Procedures

The off-hook procedures described in this section include:

Barrier Synch Loss
On-hook Request
Parallel Pickup Event Detection

5.1 Barrier Synch Loss

When in an off hook state the host must be ready to act in case of a barrier failure. The host should
attempt to put the device in an on-hook state and then reset the PLL and barrier so they can resync.

The on-hook request procedure is described in

Section 5.2

. The procedure for barrier synchronization is

described in

Section 3.2.1

.

5.2 On-hook Request

The registers used in the on-hook request procedure are:

0x12

OFH

ENDC

ENAC

ENSHL

ENLVD

ENFEL

ENDT

ENNOM

Write

0

0

0

X

X

X

X

X


Begin

1. Set ENDC = ENAC = OFH = 0 (write RG12 = 000x_xxxx).

End

5.3 Parallel Pickup Event Detection

To be defined.