2 off-hook request, Off-hook request – Maxim Integrated 73M1822/73M1922 Implementers Guide User Manual

Page 14

Advertising
background image

73M1822/73M1922 Implementer’s Guide

UG_1x22_052

14

Rev. 1.0

4.2 Off-Hook Request

The registers used in the off-hook request procedure are:

0x12

OFH

ENDC

ENAC

ENSHL

ENLVD

ENFEL

ENDT

ENNOM

Write

X/X/1/X

1/X/X/X

X/X/0 or 1/1

X

X

1/X/X/X

X

X/0/X/1

0x13

DCIV1

DCIV0

ILM

RSVD

PLDM

OVDTH

IDISPD

IDISPD

Write

VAL1[1:0]

X

X

X

X

X

X

0x14

TXBST

DAA1

DAA0

Res

RXBST

RLPNH

RXG1

RXG0

Write

X

X

X

X

0

X

X

X

0x15

Res

DISNTR

Res

CIDM

THEN

ENUVD

ENOVD

ENOID

Write

X

X

0

0/X

X/1

X

X

X

0x16

TXEN

RXEN

RLPNEN

ATEN

FSCTR3

FSCTR2 FSCTR1 FSCTR0

Write

X/1

X/1

X

X/1

VAL2[3:0] / X


The temporary variables defined in this procedure are:

VAL1 = System appropriate value for DCIV[1:0].
VAL2 = System appropriate value for FSCTR[3:0].

Begin

1. Set RXBST = 0 (write xxxx_0xxx to RG14).

2. Set CHPSEN = CIDM = 0 (write xx00_xxxx to RG15).

3. Set ENDC = ENFEL =1 (write x1xx_x1xx to RG12).

4. Set DCIV[1:0] = VAL1 (write VAL1[1:0]xx_xxxx to RG13).

5. Set FSCTR[3:0] = VAL2 (write xxxx_VAL2[3:0] to RG16).

6. Set THEN = 1 (write xxxx_1xxx to RG15).

7. Set ENNOM = 0 (write xxxx_xxx0 to RG12).

8. Set TXEN = RXEN = ATEN = 1 (write 11x1_xxxx to RG16).

9. Set OFH = 1. If using sieze state, set ENAC =0 else set ENAC =1. (write 1x0x_xxxx or 1x1x_xxxx to

RG12).

10. Wait until line settles (typical maximum is 350ms).

11. Set ENAC = ENNOM =1 (write xx1x_xxx1 to RG12).

End