FILE TRANSFER 

 
File transfer allows the user to transfer all information stored in one SC 1216 Plus to a second SC 1216 Plus. You must 
connect the units using a 3‐pin CLR cable. The unit sending the information will have the cable plugged into the DMX 
OUT plug and the receiving unit will have the cable running into the DMX IN location. 
 

TO SEND A FILE DUMP: 

 
           1) With the power turned off to the unit, press and hold down the SCANNER 2 and SCANNER 3 buttons  
                & SCENE 1 button at the same time. 
           2) Turn the unit power on while pressing these three buttons, the LCD display will read "TRANSMIT" indicating 
                that the unit is ready to send the files. 
           3) Press SCENE 7 and SCENE 8 buttons at the same time to send the file dump. 
           4) If an error occurs during the file dump, the LCD display will read "ERROR". 
 

RECEIVE FILE DUMP: 

 

           1) With the power turned off to the unit, press and hold down the SCANNER 8 and SCANNER 9 buttons  
                & SCENE 2 button at the same time. 
           2) Turn the unit power on while pressing these three buttons, the LCD display will read "RECEIVE" indicating 
                that the unit has received the file dump. 
           3) When receiving is over, the unit will automatically return to normal mode. 
 

MIDI CHANNEL SETTING: 

 

 
           1) Press and hold the MIDI/REC button for three seconds. The LCD shows the MIDI channel of last time.  
           2) Use the BANK up/down button to select the DMX channel 01‐16 to assign to the MIDI channel. 
           3) Press and hold the MIDI/REC button to save your settings. The LEDs will flash three times indicating that the 
                required operation has been performed.  

TROUBLESHOOTING 

 
If your unit does not turn on: 
 

 Check the  main power source is fully functional 
 Check power cord connection on each side 
 Check to make sure your power button is in the correct position. 

 

There are no serviceable parts inside this device. Maintenance and service operations are only to be carried out by 
authorized dealers. Contact the nearest dealer or service center for assistance with operating your unit. Unauthorized 
tampering can cause additional damage. All units opened by an unauthorized user will not be covered under warranty. 
 
For additional information regarding operation of the unit or if you have a unit to be sent in for service*,  
contact the OmniSistem Technical Department at 253‐395‐9500 Monday – Friday  10am ‐ 4pm PST.

 

 
* All service items must be given an RA# prior to shipping to our facilities. You can acquire a RA # by calling our offices 
during regular business hours. All service items must be shipped with a copy of original receipt if purchased within a year 
and covered under our warranty policy. If the unit has been modified warranty is void.

 