SCENES 

 
 

PROGRAMMING A SCENE: 

 

           
           1) Enter program mode 
           2) Check the blackout key and verify the LED is not lit. If the LED is lit, press it once to exit black‐out mode. 
           3) Verify the speed and fade time sliders are positioned at zero. 
           4) Press the scanner button corresponding to the unit you want to control. It is possible to control more than  
               one scanner at a time by pressing the button corresponding to the scanner(s) you wish to program. 
           5) Move the faders and joystick to the desired position. Selection of page B  to control channels 9‐16 is possible. 
           6) Tap the BANK up/down buttons to choose the bank you want to store this scene in. There are a total of 30 
                selectable banks. Eight scenes can be stored per bank. 
           7) Once all scanners are programmed into the desired position for the scene, tap the MIDI/RAC button to program   
                this scene into memory.  
           8) Tap the scene button you want to allocate to store your scene.  All LEDs will flash three times signifying your 
                scene has been stored. The LCD readout will show the bank and scene. 
           9) To unselect the scanner(s) you have been programming and switch to another simply press the button of the 
                scanner you have been programming again, deselecting it, and select another scanner. 
         10) Repeat steps 2‐7 until all scenes have been programmed. 
         11) If you do not intend to continue programming, press and hold the PROGRAM button for three seconds to exit 
               program mode. The LED will go out indicating this selection.  
 
 
           EXAMPLE: 
 
           1) Program enable. 
           2) Tap the Scanner 1 button to turn on its fader control. 
           3) Verify that the page select is set on page A, if not press the page select button to select page A. 
           4) Move the first and second faders all the way up to their maximum value position. 
           5) Select bank 1 using the BANK up/down buttons. 
           6) Press the MIDI/REC button. 
           7) Tap scene 1 to store the first scene. 
           8) Repeat steps 4‐7 until all scenes have been programmed into bank 1. 
           9) Tap the scanner 1 button to turn off the fader control. 
         10) When finished, disable program mode. You can now manually tap through you have just programmed. 
 
 
 

EDITING A SCENE: 

 

  
           1) Program enable. 
           2) Press the BANK up/down button to select the bank containing the scene 
           3) Select the scene you wish to edit by tapping its scene button 
           4) Use the faders and/or joystick to make the desired adjustments to the scene. 
           5) Once you have completed the changes, tap the MIDI/REC button.  
           6) Tap the scene button that corresponds to the scene you are editing. This will override the existing scene. 
 
           Be sure to select the same scene in steps 3 and 6, otherwise you may accidentally record over an existing scene. 
 
 