Solvline Eddy Series Ver 2.1a User Manual

Page 68

Advertising
background image

Chapter 5. Configuration via Web

5-8

Menu

Default

Descriptions

Bypass Enable

This needs to be set when consecutive data from the given serial
port needs to be transmitted to socket at once.


If 100 bytes of character string are to be transmitted from the

serial device and bypass is set to Disable, Eddy waits until the
entire 100 bytes are received. The maximum size to be

transmitted at once is 1500 bytes.

Eddy waits in idle state for 5-byte incoming interval, calculated by
the communication speed after the last incoming data. If no data

is received during this time, Eddy transmits all remaining data to
the server in one packet.


If set to Enable, however, few bytes’ pieces are transmitted right

away in a packet, therefore multiple packets sent to the server.

This helps in real-time communication, but might cause

tremendous traffic on the network.

Port Login

Disable

When the Operation Mode is set to TCP Server, ask for the

username and password when the client tries to connect
(Options: Enable, Disable)

Passive

Username

conuser

When the Operation Mode is set to TCP Server, set the username

to ask for. 32 Characters at maximum.

Passive
Password

99999999

When the Operation Mode is set as TCP Server, set the password to
ask for. 32 Characters at maximum.





Advertising