4. CONNECTION OF REMOTE MICROPHONE RM-1100

(AUX CONTROL TERMINAL)

4.1. Notes on Connections

The maximum cable distance between the main rack and the RM-1100 is 1200 m.

Use two-core shielded cables for signal lines.

Use twisted paired cables for control lines.

Referring to the table below, select the cable to use depending on the cable length.

A maximum of eight (five when the first-in-first-out priority or individual unit priority function is used) RM-1100
units can be connected. However, the DC power supply panel may be additionally required when the JP-
0410's power capacity is insufficient depending on the system configuration.

• Cable length vs. usable cable

Under 800 m

Over ø0.9 mm

Over ø0.35 mm

Under 400 m

Over ø0.65 mm

Over ø0.26 mm

Cable length

Power/control cable

Shielded cable