3. CONNECTION OF REMOTE MICROPHONE RM-1200

3.1. Notes on Connections

The maximum distance between the main rack and the RM-1200 is 800 m.

Use cables with line resistance of less than 10

Ω.

Use twisted paired cables for bus lines.

Use two-core shielded cables for signal lines.

When connecting the bus line to the RM-1200, be sure to use the RM-1200's BUS1 terminal.

Be sure to observe the correct polarity when connecting the bus line.

• Connections of multiple RM-1200 units

When connecting two or more RM-1200 units, be sure to branch each cable at the main rack.

Up to 8 RM-1200 units

RM-1200

RM-1200

Distance (a + b + c) must be shorter than 800 m.

(a)

(b)

Main rack

Main rack

Main rack

(c)

A maximum of eight RM-1200 units can be connected. However, the DC power supply is additionally required
when the JP-0410's power capacity is insufficient depending on the system configuration.

Make connections so that the total cable distance between the main rack and the RM-1200 is shorter than 800 m.