Battery status, Select interface – Crestron electronic STX-1700CXP User Manual

Page 13

Advertising
background image

Crestron STX-1700CXP

2-Way RF Wireless Touchpanel

Operations Guide – DOC. 6144

2-Way RF Wireless Touchpanel: STX-1700CXP

9

BATTERY STATUS

SELECT INTERFACE

CRESNET INTERFACE MENU

03

RF SETUP

Battery Status

To access the Battery Status screen, shown to the left, press the Battery Status
button on the SETUP MENU.

This screen indicates the amount of charge (or life) remaining in the battery as a
percentage of full capacity, if the battery is installed. An analog bar is provided
below the percentage amount as a quick visual reference to the approximate level of
charge remaining. The EXTERNAL POWER label appears if external power is
applied either through the docking station or via the optional power pack. Note that
battery recharging takes place only through the docking station. Touch the Return
button to display the SETUP MENU.

NOTE: When charging the battery, the battery status screen is not an accurate
indicator of battery level. The battery status screen will indicate a full charge (100%)
before the docking station indicates that charging is complete (RDY illuminates).

Select Interface

The touchpanel communicates with a control system to activate commands or to
display feedback from components within the system. The communication interface
must be correctly specified or communication will not occur. To set communication
parameters, first select the Interface button on the SETUP MENU to display the
SELECT INTERFACE screen, shown to the left. Then, select either the CRESNET
or the RF button to display the CRESNET INTERFACE MENU or the RF SETUP
screen, respectively. Use these screens to set the Cresnet network identity
(CRESNET ID) and the RF ID numbers.

Cresnet Interface Menu
CRESNET ID is a two-digit hexadecimal number that can range from 03 to FE. Note
that if the panel is to be used in a wired mode, this number and the NET ID set in the
SIMPL Windows program of the Cresnet system must match. NET ID for the STX-
1700CXP is factory set to 03.

The UP and DOWN buttons increase and decrease the CRESNET ID by one digit
(i.e., 03, 04, 05, . . .FE).

Select the Return button to return to the SELECT INTERFACE menu.

RF Setup
The RF ID identifies the gateway port that the touchpanel will use for
communication. The RF ID consists of a one-digit hexadecimal number. The
touchpanel can be set to one of fifteen numbers; “1” is shown as an example in the
illustration and is the default. This means that up to fifteen touchpanels can
communicate with a given gateway.

The UP and DOWN buttons increase/decrease the RF ID by one, respectively (i.e.,
1, 2, 3, …F).

The radio frequency channel setting (RF CHANNEL) identifies the particular TPS-
RFGWX gateway used for communication with the touchpanel. (Up to sixteen TPS-
RFGWX gateways can exist in a SIMPL program.) The RF CHANNEL setting
consists of a one-digit hexadecimal number; “0” is shown as an example in the
illustration on the left and is the default. The UP and DOWN buttons increase and
decrease the RF CHANNEL by one, respectively (i.e., 1, 2, 3, …F). Refer to the
latest revision of the TPS-RFGWX Operation Guide (Doc. 5847) for more
information on setting up the RF CHANNEL for the RF gateway.