B] cleaning procedure – Twin Eagles AM-50BAE-AD User Manual

Page 21

Advertising
background image

21

U1VA6060209

[b] Cleaning Procedure

The cleaning process will remove lime deposits from the water system.

1) Remove all ice from the evaporator and the storage bin.

Note: To remove cubes on the evaporator, move the control switch to the “OFF" position

and move it back to the “ICE" position after 3 minutes. The defrost cycle starts and
the cubes will be removed from the evaporator.

2) Move the control switch to the “OFF" position. Close the water supply line shut-off valve.

3) Disconnect the suction tube by compressing

both plastic tabs to unlock the joint in the
direction of the black arrows and pulling the
tube clear.

4) Spread out the tabs on both sides of the water

tank to unlock it, then pull it out toward you.
Drain the tank.

5) After draining, slide in the water tank along the

rails at the bottom of the right and left brackets
until it clicks into place.

6) Refit the suction tube onto the water tank inlet

by pushing the joint to lock it securely in the
direction of the arrows. A loose fitting may
cause a water leak.

7) Slowly pour the cleaning solution into the water tank.

8) Move the control switch to the “WASH" position.

9) After circulating the cleaning solution for about 30 minutes, move the control switch to the

“OFF" position.

Unlock

Unlock

Lock

Lock

Bracket

Rail

Rail

Water Tank

Joint

Drain

Suction Tube

Advertising