[e] Adjustment at Part Replacement

The thermistor and electronic controller are designed for optimum ice production. If adjustment
is desired at part replacement, follow the instructions below.

The variable resistor VR1 is for a fine adjustment of the defrost cycle completion temperature.
It needs no adjustment at part replacement.

The variable resistor VR2 is for a fine adjustment of the freeze cycle completion temperature.
Turn VR2 clockwise for a higher temperature (WARM), i.e. ice cubes with larger diameter
holes and counterclockwise for a lower temperature (COLD), i.e. ice cubes with smaller
diameter holes.

Note: Do not adjust VR2 to the lowest temperature. It will cause excessive ice production

resulting in defrost failure.

Fig. 8

Electronic Controller

Variable resistor for

adjustment of freeze cycle

completion temperature

Variable resistor for

adjustment of defrost cycle

completion temperature

(Does not need adjustment)