37

U1VA6060209

PROBLEM

CHECK

POSSIBLE CAUSE

REMEDY

[6] Water will not be
supplied

a) Water Supply

1. Cut off

1. Turn off power supply and
wait for recovery

2. Shut-off Valve or water
tap closed

2. Open

b) Water Valve

1. Filter clogged

1. See "IV.3. Water Valve"

2. Coil winding opened

2. Replace

[7] Water continues to be
supplied in freeze cycle

a) Water Valve

1. Diaphragm does not
close

1. Check for water leaks
with icemaker off

b) Electronic Controller

1. Defective

1. Replace

[8] No water comes from
water tank

a) Wiring to Pump Motor

1. Loose connectors or
broken wire

1. Repair or replace

b) Pump Motor

1. Coil winding opened

1. Replace

c) Pump Motor Impeller

1. Defective or bound
impeller

1. Replace and clean

d) Pump Motor Capacitor

1. Defective

1. Replace

e) Water System

1. Water leaks

1.Check connections for
water leaks and repair

2. Clogged

2. See "IV.1. Cleaning and
Sanitizing Instructions"

f) Water Supply Line

1. Water pressure too low
and water level in water tank
too low

1. Check for recommended
pressure

[9] All components run but
no ice is produced

a) Water System

1. Water leaks

1. Check connections for
water leaks and repair

2. Clogged

2. See "IV.1. Cleaning and
Sanitizing Instructions"

b) Nozzle

1. Clogged

1. See "IV.1. Cleaning and
Sanitizing Instructions"

2. Misaligned nozzle and
water tank

2. Place in correct position

a) Refrigerant Circuit

1. Gas leak

1. Check with a leak
detector. Weld, vacuum and
recharge. Replace the
refrigerant drier.

2. Undercharged

2. Check for leaks and
recharge.

3. Air or moisture trapped

3. Replace drier & recharge

b) Compressor

1. Defective valve

1. Replace compressor

c) Hot Gas Valve

1. Continues to open in
freeze cycle

1. Check and replace

d) Water Valve

1. Stuck open

1. Clean or replace

a) Ambient temperature

1. Low

1. No problem. Low ambient
temperature results in ice
cubes with slightly larger
diameter holes.

b) Electronic Controller

1. Built-in timer does not
count 10 min

1. Replace

[10] Large-hole cubes