8. Water Valve

1) Close the water supply shut-off valve.

2) Unplug the icemaker or disconnect the power source.

3) Remove the door and top panel.

4) Disconnect the receptacle (leads) from the water valve.

5) Remove the valve outlet tubing.

6) Remove the water supply inlet and water valve by releasing the two retaining screws.

7) Install the new valve in the reverse order of the removal procedure.

8) Open the water supply shut-off valve.

9) Plug in the icemaker or connect the power source.

10) Check for leaks.

11) Refit the panels in their correct positions.

Note: When replacing parts, disassemble as shown in Fig. 7 (page 25) and replace the

defective parts.

9. Controller Board

1) Unplug the icemaker or disconnect the power source.

2) Remove the louver and door.

3) Remove screws and the control box cover.

4) Pull out the control box from the machine compartment, and disconnect the connectors on

the controller board.

5) Pull out and remove the controller board from the control box.

6) Install the new controller board and reassemble the control box in the reverse order of the

removal procedure.

7) Refit the panels in their correct positions.

8) Plug in the icemaker or connect the power source.

Advertising