U1VA6060209

[d] Before Checking the Electronic Controller

Check the power source voltage and the thermistor as shown in the table below.

* Disconnect the thermistor on the
board.
* Remove the screw and the
thermistor holder on the evaporator.
* Immerse the sensor part in a glass
containing ice and water for 5
minutes.
* Check the resistance between
terminals of the thermistor.
* Replace the thermistor in its correct
position.
* Connect the thermistor.

Component

Procedure

Normal

5.5 - 6.5 k

CAUTION

Thermistor sensor part is fragile,
glass sealed. Handle with care.

Thermistor
(on evaporator)

Thermistor

Evaporator