SECTION 3

CARE OF YOUR FILTER

3C. REPLACING MINERAI_______ TASTE & ODOR FILTER

Average life of the activated carbon mineral bed is

about 1 year (see page 12). It's time to replace the

bed when the tastes and/or odors begin to return in
the water supply. Do the following.

STEPS TO REPLACE MINERAL

1,

Press the face plate BACKWASH NOW

button and

hold

for 3 seconds, until RCHG

begins to flash in the display.

2.

When water begins to flow from the valve drain

hose, place the bypass valve(s) in

BYPASS

position .. . see FIG. 8, page 18.

8

.

Stand the tank upright and replace the bottom

distributor assembly. Temporarily, plug the top
end of the distributor (use rag, etc.) to prevent
accidental mineral spills into it.

9

.

Using a large neck funnel (FIG. 6), first add 17

lbs. of gravel, followed by 10 lbs. of filter sand.
Next, add the 1 cu. ft. of activated carbon. Use

water sparingly to assist carbon flow th rough the
funnel.

NOTE:

Be sure the bottom distributor is centered in the tank

while adding mineral.

CAUTION:

BE SURE TO DO STEPS 1 AND 2 AS INSTRUCTE D,

TO RELIEVE WATER PRESSURE IN THE TANK.

10. Use water to flush the tank top opening. Then,

replace the top distributor and 3 o-rings. Be sure

to locate o-ring seals correctly... FIG. 7, page

14.

3

.

Unplug the transformer at the wall outlet.

4

.

Carefully, pull the 2 clips (key #41, page 26) at

the inlet and outlet fittings. Slide the adaptors, or
bypass valve, from the filter valve.

5

.

Referring to FIG. 7, page 14, remove the clamp

retainers (2) and clamp sections (2) that hold the
valve to the tank. Lift upward to remove the
valve.

6

.

Remove the o-rings (3) and top distributor from

the top of the tank.

7.

Next to a floor drain, carefully tip the tank over,

catching the used carbon in a burlap sack or
other suitable container. Remove the bottom
distributor assembly, and flush the inside of the
tank with water.

11. Carefully, install the valve assembly and retain­

ing clamps. DOUBLE-CHECK TO BE SURE
CLAMPS AND RETAINERS ARE SECURELY
FASTENED IN PLACE.

12. Referring to your installation manual, reconnect

the filter to the plumbing. BE SURE THE PLUMB­

ING IS HELD FIRMLY IN PLACE, IN THE VALVE
INLET AND OUTLET.

13

.

Place the valve drain hose at the drain point and

secure in place.

14

.

Return the plumbing bypass valve(s) to SERV­

ICE position.

15. Plug the transformer into the wall outlet. The

filter will complete the backwash cycle, started in
step 1, and will automatically return to service.

CAUTION:

NOTE:

HANDLE THE TANK CAREFULLY. FULL OF WATER

AND CARBON, IT IS VERY HEAVY. DO NOT

ATTEMPT TO LIFT IT BY YOURSELF. DO NOT

DROP AND BREAK THE TANK.

All new carbon mineral contains some smaller than

normal particles called "fines." Backwashing the filter
removes the fines. If, after the backwash in step 15

is over, fines are still in the filtered water, repeat step
1 for added backwashing.