EXTERNAL STATIC PRESSURE

(Inches of Water Column)

"INPUT

(BTU/HR)

MINIMUM

MAXIMUM

40,000

0.10

0.50

60,000

0.12

0.50

80,000

0.12

0.50

100,000

0.15

0.50

120,000

0.20

0.50

140,000

0.20

0.50

‘Input is on furnace rating plate on blower door.

FIGURE 24

A. Supply air duct work.

NOTE: Supply air duct (plenum) connection must be the
same size as the furnace supply air opening. Attach to

furnace duct flanges.

If you install furnace in horizontal position with an air

conditioner, design a minimum 18" long transition that

allows free air flow through furnace and cooling coil. Make
sure furnace temperature rise is within range noted on
furnace rating plate. Also, consult air conditioner's duct
work installation Instructions.

Seal supply air duct work to furnace casing, walls, ceilings
or fioors it passes through. End duct work outside furnace
space.

B, Return air duct work.

1.

In upflow position, return air duct must be a mini­
mum depth of 23-31/32". See Figure 25.

2.

In downflow position, return air duct must be a mini­

mum 19-7/8" inside depth. See Figure 26.

CASING
WIDTH
14.50

20.50
23.50

FIGURE 25

NOTE: In upflow position, if bottom return air is not

used, you must attach a solid bottom closure panel
to bottom return air opening. Bottom closure panel is
available from manufacturer as follows:

BTU/HR"

MOTOR*

BOTTOM CLOSURE

INPUT

H.P.

PART NUMBER

40,000

1/4

40,000

1/3

4045900

60,000

1/4

60,000

1/3

60,000

1/2

4045901

80,000

1/4

4045900

80,000

1/3

80,000

1/2

4045901

80,000

3/4

4045902

100,000

1/3

4045901

100,000

1/2

100,000

3/4

120,000

1/2

4045902

120,000

3/4

140,000

3/4

4045903

140,000

3/4

"See furnace rating plate on blower door.