b. The minimum capacity (Fan Min.) shaH be

determined

by

referring

to

the

corresponding single appliance table

(Tables 1 and 2). In this case, for each
appliance the entire vent connector and
common vent from the appliance to the
vent termination would be treated as a
single appliance vent, as if the other
appliances were not present.

5)

If vent connectors are combined prior to

entering the common vent, the maximum

common vent capacity listed in the common
venting tables must be reduced by 10%. the
equivalent of 1 (one) 90® elbow (0.90 x
maximum common vent capacity). See Figure

11

The horizontal length of the common vent

connect or manifold (L) should not exceed

1-1/2 feet (18 inches) for each inch of

common vent connector manifold diameter.

6)

If the common vertical vent is offset as shown
in Figure 8. the maximum common vent

capacity listed in the common venting tables

should be reduced by 20%, the equivalent of
2 (two) 90® elbows (0.80 x maximum common
vent capacity). The horizontal length of the
offset shall not exceed 1 1/2 feet for each
inch of common vent diameter.

7) The common vent diameter must always be at

least as large as the largest vent connector
diameter. All interconnection fittings must
also be the same size as the common vent.

8)

Type 6 gas vents shall terminate above the
roof surface with a listed cap or a listed roof
assembly in accordance with the terms of their
respective

listings

and

the

vent

manufacturer's instructions.

VENT CAPS 12" AND SMALLER
Listed gas venting systems using listed vent
caps 12" and smaller in size may terminate in
accordance with the VENT TERMINATION

TABLE. (SEE FIGURE 1)

VENT CAPS LARGER THAN 12"
Listed ve/it caps

larger

than 12" must be

located at least 2 feet above the highest point
and at least 2 feet higher than any portion of a
building within a horizontal distance of 10

Feet. (SEE FIGURE 2)

9)

Use sea level input rating when determining

maximum capacity for high attitude installation.
Use actual input rating for determining
minimum capacity for high attitude installation.

GAS VENT TERMINATION TABLE

ROOF PITCH

MINIMUM HEIGHT

FLAT TO 7/12

1.0 FEET *

OVER 7/12 TO 8/12

1.5 FEET

OVER 8/12 TO 9/12

2.0 FEET

OVER 9/12 TO 10/12

2.5 FEET

OVER 10/12 TO 11/12

3.25 FEET

OVER 11/12 TO 12/12

4.0 FEET

OVER 12/12 TO 14/12

5.0 FEET

OVER 14/12 TO 16/12

6.0 FEET

OVER 16/12 TO 18/12

7.0 FEET

OVER 18/12 TO 20/12

7.5 FEET

OVER 20/12 TO 21/12

8.0 FEET

* THIS REQUIREMENT COVERS MOST INSTALLATIONS